Oximeter Normal Level



  1. Normal Oximeter Reading Range
  2. Normal Oximeter Levels By Age
  • What are vital signs?
  • What is a normal oximeter reading?

Vital signs are measurements of the body’s basic functions. Normal vital signs change with age, sex, weight, exercise tolerance, and overall health. The four main vital signs that are usually monitored include:

A pulse oximeter may be a helpful tool to monitor oxygen levels at home if you suspect you have Covid-19. Here's what doctors want you to know about normal oxygen levels and those that might be a. Your pulse oximeter will give you a numerical reading — a percentage that indicates the level of oxygen saturation in your blood. If you’ve been to a doctor in the past 20 years, you’ve. Hypoxemia is a below-normal level of oxygen in your blood, specifically in the arteries. Hypoxemia is a sign of a problem related to breathing or circulation, and may result in various symptoms, such as shortness of breath. Hypoxemia is determined by measuring the oxygen level in a blood sample taken from an artery (arterial blood gas). According to the Mayo Clinic, normal pulse oximeter readings usually range from 95 to 100 percent. Values under 90 percent are considered low, and indicate the need for supplemental oxygen. This condition is often referred to as hypoxemia, and its symptoms include severe shortness of breath, increased heart rate and chest pain.

  • Body temperature
  • Pulse rate (heart rate)
  • Rate of breathing (respiration rate)
  • Blood pressure

Contents

Pulse oximeter readings chart

Often called the “fifth” vital sign, pulse oximetry is a non-invasive way to monitor oxygen saturations. Prior to the use of pulse oximeters, the amount of oxygen in the blood could only be measured by drawing blood directly from an artery and analyzing that.

Pulse oximetry is generally done by using a device placed on the end of a finger or on the earlobe. Light of two wavelengths passes through the tissue and the oxygen saturation is measured. The measurement is the percent saturation of oxygen which is being carried by hemoglobin in the blood. Hemoglobin is the oxygen carrying pigment in our red blood cells.

A normal reading is 95% to 99%. Readings below 90% often indicate that someone needs to have supplemental oxygen.

Pulse oximeter oxygen saturation

Pulse oximetry allows a rapid noninvasive estimate of arterial oxygen saturation. Since its development in the 1970s, it has made a significant impact, particularly in the fields intensive care medicine.

Most modern pulse oximeters determine arterial hemoglobin saturation through the use of two lightemitting diodes in the red (660 nm) and infrared (940 nm) spectrum.

The differential absorption of these two wavelengths of light by oxygenated and deoxygenated hemoglobin during pulsatile blood flow allows for accurate estimation of arterial oxygen saturation under most conditions.

However, pulse oximeters can give erroneous from a variety of causes, including hypoperfusion, nail polish, darker skin pigmentation, venous pulsations, and, perhaps most frequently, motion artifact.

Medical Grade Pulse oximeter

Clinicians must consider these possible causes of error when interpreting pulse oximetry results, especially those that are not consistent with a patient’s clinical status and medical history.

Clinically significant desaturations in an ambulatory setting are uncommon in patients without significant pathologic pulmonary conditions or pulmonary vascular disease.

The potential of erroneous readings must be considered, especially measurements made during exercise.

Pulse oximeter 6 minute walk test

Continuous pulse oximetry is commonly combined with a 6-min walk test (6MWT) in the ambulatory setting when evaluating dyspnea.

Prior American Thoracic Society guidelines for the 6MWT recommend against continuous monitoring of oxygen saturation during a 6MWT3 because of concerns about erroneous readings.

Prior studies have shown significant inaccuracies in this setting, likely due to motion artifact.

In addition, many handheld pulse oximeters available in the office setting do not display oximetry waveforms or alternative evaluations of measurement quality.

This leads to a greater risk of misinterpretation, as a digital readout is assumed to be accurate without a proper understanding of how that measurement is made.

6-minute walk test normal values

However, more recent European Respiratory Society/American Thoracic Society guidelines for field walking tests (including 6MWT) support the use of continuous oximetry because of evidence showing that the lowest saturation does not necessarily occur at the end of the test.

Oximeter Normal Level

Patients suspected of having desaturations by pulse oximetry during a 6MWT are regularly referred to our facility for formal cardiopulmonary exercise testing.

Normal

These evaluations are a source of significant expense, including that of the cardiopulmonary exercise testing itself, as well as risk to the patient from invasive procedures or radiation exposure that may be unnecessary if their pulse oximetry testing results were inaccurate.

Pulse oximeter uses and limitations

Applications for use:

Pulse oximetry is used extensively in medical offices and hospitals. It is also now widely used in the home setting to monitor people with heart and lung problems. Uses include:

  • Monitoring the level of supplemental oxygen needed for someone with COPD, CHF,or other diseases.
  • Monitoring someone who is ill with a respiratory infection.
  • A fall in oxygen can be a warning that the person needs further evaluation immediately.
  • Monitoring oxygen levels during sleep can help diagnose sleep apnea.

Pulse oximeter false readings

There are some limitations of this technology and can result in either falsely low or high oxygen saturation readings:

  • Low blood pressure as blood does not circulate well into the hands.
  • Hypothermia (very low body temperature) as blood vessels will constrict or narrow.
  • Motion such as shivering or seizures can affect readings.
  • Congenital medical conditions of abnormal hemoglobin or severe anemia canaffect readings.
  • Poor sugar control in diabetics has been associated with high oxygen saturation readings due to an increase in oxygen “sticking” to hemoglobin in the blood.
  • Nail polish or artificial nails could affect the reading but the probe can be placed sideways on the finger so that the pulsed light does not go through the nails. Dark skin pigmentation can also affect readings.
  • Intense daylight, fluorescent light and other intense light can cause falsely lowreadings.

More on this story

Pulse Oximeter made in USA

  • Ever wonder if there are pulse oximeters made in the USA?
  • How many medical device manufacturers are there in the United States?

FDA approved pulse oximeter

Pulse oximetry is a test used to measure the oxygen level (oxygen saturation) of the blood. It is an easy, painless measure of how well oxygen is being sent to parts of your body furthest from your heart, such as the arms and legs.

Normal Oximeter Reading Range

Fingertip Pulse Oximeters

  • What is the best pulse oximeter?
  • What is a normal oxygen saturation level?
  • Are any oximeters made in the USA?
  • Pulse oximeters FDA approved and more…

Pulse Oximeters: Answering Your Frequently Asked Questions

Normal Oximeter Levels By Age

NPR’s sites use cookies, similar tracking and storage technologies, and information about the device you use to access our sites (together, “cookies”) to enhance your viewing, listening and user experience, personalize content, personalize messages from NPR’s sponsors, provide social media features, and analyze NPR’s traffic. This information is shared with social media, sponsorship, analytics, and other vendors or service providers. See details.

You may click on “Your Choices” below to learn about and use cookie management tools to limit use of cookies when you visit NPR’s sites. You can adjust your cookie choices in those tools at any time. If you click “Agree and Continue” below, you acknowledge that your cookie choices in those tools will be respected and that you otherwise agree to the use of cookies on NPR’s sites.